KEVOR servo voltage stabilizer

20 KVA Servo Voltage Stabilizer

A 20 KVA servo stabilizer for cnc equipment and hvac loads, subject to actual load and supply conditions.

KEVOR / Servo voltage stabilizerConfigured for your load
Cream-colored KEVOR three-phase servo voltage stabilizer
Product photo. Actual configuration varies by order.
Technical overview

20 KVA technical overview

Confirm the actual load and measured input range before ordering. Starting current and simultaneous equipment operation can change the required capacity.

CNC equipmentHVAC loadsLaser and production equipment

Application examples are starting points, rather than capacity guarantees.

Rated capacity
20 KVA
Phase options
Single or three phase
Input-voltage selection
Specified from measured site voltage and phase
Standard nominal output
230 V AC single phase / 400 V AC three phase; custom output on review
Calculated nominal output current
87.0 A single phase / 28.9 A three phase
Cooling & duty
Confirmed for the selected model, load and installation
Operation
Automatic servo-controlled voltage correction
Correction principle
Servo motor-driven voltage regulation
Output tolerance & correction speed
Stated for the selected input range, load and construction
Duty, ambient & efficiency
Model-specific operating limits and performance confirmed in the technical offer
Three-phase arrangement
Confirm phase correction, neutral arrangement and permitted imbalance for a three-phase order
Protection & bypass
Standard features and optional arrangements confirmed in the technical offer
Installation
Confirm enclosure, ventilation, service clearance and cable access

Current is calculated from rated KVA at 230 V single phase or 400 V three phase; it is not the maximum input current. Dimensions, protection and performance are confirmed for the ordered configuration.

Before the quotation

Three details. One useful conversation.

01

Show us the load.

Send the machine nameplate or share its electrical rating and supply phase.

02

Check the supply.

Share the measured low and high input voltage and the installation conditions.

03

Confirm the configuration.

Review capacity, cooling, protection, delivery and warranty in the written quotation.

Compare another capacity

Explore the servo range.

Need a different range or output?
Worked example / Illustrative only

What does 20 KVA mean for a load?

A simultaneous electrical input of 12.8 kW at a measured power factor of 0.8 equals 16.0 KVA. Adding an illustrative 25% planning allowance gives 20 KVA.

This arithmetic is not a product recommendation or a motor-start allowance. Check starting demand, the load on each phase, the lowest input voltage and the machine’s supply limits before choosing capacity.

Try the KVA calculator
Include it in your technical offer

Know which protections you are getting.

Ask which items are standard, optional or supplied by the installation contractor for your model.

  • Low- and high-voltage cut-off
  • Overload and short-circuit coordination
  • Single-phasing protection for three-phase loads
  • Phase reversal and phase imbalance monitoring
  • Manual or automatic bypass arrangement
  • Metering, alarms and restart behaviour
  • Earthing and surge protection requirements
  • Enclosure, ventilation and temperature limits
Servo voltage regulation

Sense the voltage. Adjust the correction.

A servo stabilizer raises low voltage or reduces high voltage within its specified operating range.

1. Monitor

The control circuit monitors voltage and compares the measured output with the selected voltage setting.

2. Adjust

The servo motor moves the regulating mechanism to increase or decrease voltage correction.

3. Regulate

Feedback continues as the supply changes. A large voltage correction takes mechanical movement; the controller’s reaction time and the complete correction time are different.

A conventional variac-based servo design uses a variable autotransformer, a buck-boost transformer and a servo motor. The regulating arrangement and component selection are confirmed for the offered model. Voltage regulation uses the available AC supply; battery backup and electrical isolation are separate functions.

Read the specification clearly

What the technical terms mean

Input range

The incoming voltage window for the selected configuration. Confirm whether full rated load is supported throughout that window.

Nominal output & accuracy

The target voltage and permitted variation under stated conditions. The nominal value alone is not a guarantee of regulation accuracy.

Correction speed

The rate of voltage correction, normally expressed in volts per second. It varies with the selected construction.

Response time

A defined reaction interval. It should not be confused with the time needed to complete a large mechanical voltage correction.

KVA and load current

Capacity must be considered with phase, voltage, simultaneous electrical load and motor starting demand. kW and KVA are not interchangeable.

Protection & bypass

Cut-offs, overload arrangements, phase monitoring and bypass are model-specific. Confirm the actual supplied features in the technical offer.

Air & oil cooling

Air-cooled construction transfers heat to the surrounding air. Oil-cooled construction uses insulating oil in its thermal design. Cooling must suit the load, operating hours, ventilation and ambient conditions.

Frequency & waveform

Voltage correction does not replace a frequency converter or harmonic filter. Check the permitted supply frequency and any distortion limits against the equipment requirements.

Duty & temperature

Continuous duty describes operation under specified conditions; it does not mean unlimited service life. Ambient temperature and temperature rise describe different measurements.

Efficiency & losses

Efficiency depends on the operating conditions and load. Ask which input voltage and load were used for the stated figure. Regulation alone does not establish an electricity-saving percentage.

Phase balance

Three-phase selection needs the load and voltage on each phase. Confirm independent phase correction, neutral requirements and permitted imbalance for the offered design.

Standards & test reports

A standard number should identify the relevant product and test scope. Request the applicable model documents instead of treating a catalogue reference as certification.

Before you order

20 KVA price, delivery & support

Compare the complete configuration and order value before choosing a stabilizer.

What determines the price?

Capacity, phase, correction range, cooling, winding design and protection options affect the quotation. GST, packing, freight and installation should be stated separately where applicable.

Servo price guide

Pan-India door delivery

Provide the delivery address and PIN code. We confirm dispatch timing, freight and site-access requirements for the actual unit. Unloading and installation are agreed separately.

Shipping information

Warranty & after-sales

Ask for the warranty period, coverage, exclusions and service arrangement in writing. Keep the invoice and model details ready when contacting KEVOR for support.

Warranty & support
Questions, answered

Questions about 20 KVA selection.

Is 20 KVA suitable for my machine?

A 20 KVA rating does not establish suitability on its own. Check rated electrical input, phase, measured supply voltage, simultaneous loads and starting demand. Share the machine nameplate with KEVOR for a configuration review.

What affects the 20 KVA Servo stabilizer price?

Phase, input correction range, output requirement, cooling and protections affect the price. Ask for a configuration-specific quotation showing GST, freight, installation and warranty scope.

Is door delivery available?

Yes. KEVOR offers Pan-India door delivery. The quotation confirms freight, dispatch timing and unloading arrangements for your location.

What will be confirmed before I order?

The written quotation should confirm capacity, phase, input-voltage range, nominal output, cooling, protection options, price, freight, installation scope and order-specific warranty. Product dimensions and any performance figures should come from the selected configuration.

Your requirement, first

Let’s review your 20 KVA requirement.

Send your machine details on WhatsApp, or leave your number. We’ll help you take the next step.

Send a nameplatePrefer to talk? +91 76696 69400
Talk to KEVOR

Let’s find the right fit.

Just your name and number to get started.

Add technical or company details Optional

Loading security verification…

Prefer WhatsApp? Continue with these details

KEVOR will use these details to respond to your enquiry. Privacy policy.